Property |
Test Method |
Result |
Nominal Weight |
|
120g/m2 |
Nominal Thickness |
|
0.58mm |
Color |
|
Top: Orange Bottom: White |
Water Vapor Permeance |
ASTM E96 Proc. A Desiccant Method @ 23ºC |
Original 8923 ng/Pa/s/m² or 156.1 perms UV and Heat Aged 10,433 ng/Pa/s/m² or 182 perms |
Water Ponding UV and heat-aged samples |
CCMC 07 25 10.03-2011 |
No leakage- Pass |
Moisture Vapor Transmission Rate (MVTR) |
BS 3177 |
Minimum 1500 gm/m2/ 24 hrs |
Vapor Resistance |
BS 3177 |
0.21 MNsg-1 |
Tensile Strength |
ASTM D882 ASTM G154(UV) |
Original 4.79 N/mm UV and Heat Aged 4.34 N/mm |
Breaking Force |
ASTM D5034 |
MD 345 N CD 252 N |
Surface Burning Characteristics |
ASTM E84 |
FSI 20 Class A SD 185 Class A |
Low Temperature Flexibility |
AC 38 |
Pass |
Ultraviolet Exposure |
AC 38 |
Pass |
Accelerated Aging |
AC 38 |
Pass |
Water Ponding |
AC 38 |
Pass |
Air Permeance |
ASTM 2178 per AC 38 |
0.0002 L/s-m2 @ 75 Pa (No Air Leakage) |