PROPERTY

TEST METHOD

MINIMUM VALUE

Tensile Strength

ASTM D412

62 lbs/in MD 
47 lbs/in CD

Tensile Strength, 
UV Aging

ASTM D412

73 lbs/in MD
52 lbs/in CD

Tensile Strength, Weathered

ASTM D412

65 lbs/in MD
64 lbs/in CD

Pliability, 
14 degrees F      

ASTM D146

Pass

Water Vapor Transmission

ASTM E96

0.019 g/hr/sq.m (max)

Peel Adhesion

ASTM C794

19 lbs/in

Peel Adhesion, 
7-day, Water

ASTM C794

13 lbs/in

Peel Adhesion, 
210 Hrs, UV

ASTM C794

11 lbs/in

Cycle Over, 
20 degrees F

ASTM C836

Pass